Elenco 23 Range 20k/V VOM in Kit Form Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Elenco 23 Range 20k/V VOM in Kit Form. Elenco 23 Range 20k/V VOM in Kit Form User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ANALOG MULTIMETER KIT
MODEL M-1250K
Copyright © 2007, 2000 by Elenco
®
Electronics, Inc. All rights reserved. Revised 2007 REV-H 753070
No part of this book shall be reproduced by any means; electronic, photocopying, or otherwise without written permission from the publisher.
Elenco
®
Electronics, Inc.
Assembly and Instruction Manual
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - ANALOG MULTIMETER KIT

ANALOG MULTIMETER KITMODEL M-1250KCopyright © 2007, 2000 by Elenco®Electronics, Inc. All rights reserved. Revised 2007 REV-H 753070N

Pagina 2 - PARTS LIST

-9-INSTALL BATTERY CLIPSInstall the PC board into the case (see Figure O).Align the buzzer holder over the two posts and press it down in place (see F

Pagina 3

-10-CALIBRATIONBatteriesInstall the following parts:1. Install the 9V and the two 1.5V (AA) batteries as shown in Figure 1. Be sure to observe the po

Pagina 4 - IDENTIFYING CAPACITOR VALUES

-11-INSTALL BACK COVER AND 0Ω ADJ KNOBInstall the bottom case and mount into place with an M4 x 10 screw as shown in Figure Q.Place the 0Ω ADJ knob on

Pagina 5 - Figure A

-12-TROUBLESHOOTING CHARTThis chart lists the condition and possible causes of several malfunctions. If a particular part is mentioned asa possible c

Pagina 6 - Figure F

-13-OPERATING AND TESTING THE MULTIMETERCAUTION: When measuring an unknown voltage or current, always start with the range switch set to thehighest sc

Pagina 7 - Figure G

-14-AC Voltage TestIn reading AC voltage, it is necessary to obtain a known source of AC. A 12 volt transformer is preferred. If oneis not available,

Pagina 8 - ASSEMBLE THE BUZZER

-15-THEORY OF OPERATIONIntroductionYour multimeter is of professional quality using 1% precision resistors throughout the design. The accuracy atfull

Pagina 9 - Figure N

-16-DC Current MeasurementFigure 6 shows a simplified diagram of the DC current measuring circuit. Here the resistors are placed acrossthe meter to s

Pagina 10 - INSTALL BATTERY CLIPS

hFE MeasurementFigure 8 shows a simplified diagram of the hFE measuring circuit for PNP transistor. Here the range switch is inthe X10 ohms position

Pagina 11 - CALIBRATION

SCHEMATIC DIAGRAM M-1250K-18-Pin-out2SC18152SA1015E C B

Pagina 12 - Figure Q

PARTS LISTIf you are a student, and any parts are missing or damaged, please see instructor or bookstore.If you purchased this kit from a distributor,

Pagina 13 - TROUBLESHOOTING CHART

Elenco®Electronics, Inc.150 Carpenter AvenueWheeling, IL 60090(847) 541-3800Web site: www.elenco.come-mail: [email protected]

Pagina 14 - Ohms Test

-2-* These parts are part of the main rotary switch assembly. This may come preassembled by the factory.SEMICONDUCTORSQty. Symbol Value Description P

Pagina 15

IntroductionAssembly of your M-1250 Analog Multimeter Kit will prove to be an excitingproject and give you much satisfaction and personal achievement.

Pagina 16 - THEORY OF OPERATION

-4-ASSEMBLE COMPONENTS TO THE PC BOARDAfter each step, put a check in the box located next to the step that you have completed.Place the PC board on a

Pagina 17 - DC Current Measurement

-5-C3 - .047μF Discap (473)R29 - 820kΩ 1% 1/4W Resistor(gray-red-black-orange-brown)Q1 - C1815 Transistor(see Figure C)R30 - 260kΩ 1% 1/4W Resistor(re

Pagina 18 - Buzzer Test

-6-ASSEMBLE COMPONENTS TO THE PC BOARDAfter each step, put a check in the box located next to the step that you have completed.R28 - 3MΩ 1% 1/2W Resis

Pagina 19 - SCHEMATIC DIAGRAM M-1250K

ASSEMBLE THE BUZZERTin the buzzer in the three locations shown in Figure Ka.Tin both ends of the 3.5” red, white, and green wires as shown in Figure K

Pagina 20 - Electronics, Inc

SOLDER METER MOVEMENT WIRES TO PC BOARDTin the ends of the meter wires. Solder the red meter wire to M+ and the black wire to M– on the foil side oft

Comentarios a estos manuales